    ȸÀü ³óÃà±â , RV10-control-D [3560000]
    ÆǸŰ¡°Ý 4,950,000¿ø
    ¿ø»êÁö µ¶ÀÏ
    ºê·£µå IKA
    Á¦Á¶»ç IKA
    Á¦Ç°ÄÚµå RV10-control-D [3560000]
    ÁÖ¹®¼ö·®
    »ó¼¼¼³¸í »óÇ°Èıâ(0) »óÇ°¹®ÀÇ(0) ±³È¯ ¹× ¹ÝÇ°/¹è¼Û/°áÁ¦




    ¤· IKA ȸÀü Áõ·ùÀåÄ¡ÀÇ Æ¯Â¡

    - RV10 rotavapor Á¦Ç°µé¿¡ ¾ÈÀüÁ¤Áö±â´ÉÀ» ÀÚµ¿¸ðÅ͸®ÇÁÆ®ÀåÂø

    - ¾ç¹æÇâȸÀü, smooth start, ÃÖÀú À§Ä¡¼³Á¤, µ¹¹ß»óȲ½Ã ÀÚµ¿¸®ÇÁÆ®±â´É ¹× ŸÀÌ¸Ó ±â´É¿¡¼­ ¼³Á¤È®Àΰ¡´É

    - RV10 digital Á¦Ç°Àº ¿Âµµ µð½ºÇ÷¹ÀÌ¿Í RS232 interface °¡ ÀåÂøµÇ¾î ÀÖ½À´Ï´Ù.

    developed product line from IKA¢ç in ergonomic, compact design with innovative functions to improve operating results. Rotary evaporators with integrated heating bath HB 10 digital (3 litre)incl. dry ice condenser.

    - Heating bath with adjustable safety circuit, "stand alone" operation possible, pivoting safety hood as accessory
    - Safe and simple operation through ergonomically shaped operator unit in the front area
    - Motorized lift (stroke 140 mm) with "safety stop" function, if the power cuts out the evaporator piston is automatically lifted out of the heating bath.
    - Adjustable end position recognition to protect the glass from breaking
    - Speed range from 20 to 270 rpm
    - Smooth start from 100 rpm
    - Digital speed display
    - Moves right and left in interval operation for the drying process
    - Timer function for time lapse controls
    - Water-oil heating bath with integrated carry handles with safe handling
    - Heats up quickly because of optimized bath volumes
    - Cooling surface 1,200 cm©÷
    - Push-off mechanism to loosen tightly fitting pistons
    - Digital water - oil heating bath with integrated carry handles
    - Temperature control of the heating bath by a micro controller
    - Digital temperature display
    - Infrared interface for data transfer from the heating bath to the drive unit
    - RS 232 interface for PC remote operation with labworldsoft
    - Automatic operation with labworldsoft
    - Integrated vacuum controller with central display for ramp programming
    - Integrated solvent library, extendible by the client
    - Distillation specific parameters stored for standard distillation
    - Automatic transfer of measurements and distillation type with one key press
    - Volume controlled distillation processes programmable
    - Automatic boiling point recognition
    - Color graphic display for safe and comfortable device operation
    - Display of distillation curves
    - Multiple languages
    - Automatic ventilation after the end of the test
    - Cooling water switched off automatically after the end of the test
    - Integrated cooling water monitoring
    - Heating bath safety management: automatic heating bath monitoring with distillation stop in case of temperature errors
    - Heating bath switched off automatically after the end of the test
    - USB interface
    - Suitable for DIN EN 12697-3 (Asphalt test for hot asphalt)

    Type of cooling vertical
    Cooling surface 620 cm2
    Motor principle DC
    Speed range 20 - 280 rpm
    Reversible direction of rotation yes
    Lift Motor
    Stroke 140 mm
    Heating temperature range room temp. - 180 ¡ÆC
    Heat output 1300 W
    Heat control accuracy 1 ¡¾K
    Bath volume max. 3 l
    Vacuum controller integrated yes
    Measurement accuracy +/- 2 mbar
    Vacuum adjustment range 1050 - 1 mbar
    Vacuum measurement range 1050 - 1 mbar
    Timer yes
    Dimensions (W x H x D) 500 x 430 x 410 mm
    Weight 21.5 kg
    Permissible ambient temperature 5 - 40 ¡ÆC
    Permissible relative moisture 80 %
    Protection class according to DIN EN 60529 IP 20
    RS 232 interface yes
    Voltage 220 - 240 / 100 - 120 / 100 - 115 V
    Frequency 50/60 Hz
    Power input 1400 W

     

    ¹«´Ü¼öÁý¹× º¹À縦 ±ÝÇÕ´Ï´Ù .
    »óÇ°Á¤º¸°í½Ã
    Á¦Ç°¸í ȸÀü ³óÃà±â , RV10-control-D [3560000]
    ÆǸŰ¡°Ý 4,950,000¿ø
    ºê·£µå IKA
    ¿ø»êÁö µ¶ÀÏ
    Á¦Á¶»ç IKA
    °ü·Ã»óÇ°
        
    »ó¼¼¼³¸í »óÇ°Èıâ(0) »óÇ°¹®ÀÇ(0) ±³È¯ ¹× ¹ÝÇ°/¹è¼Û/°áÁ¦
    ¹øÈ£ Á¦¸ñ À̸§ º°Á¡ ³¯Â¥
    ¾ÆÁ÷ ÀÛ¼ºµÈ »óÇ°ÆòÀÌ ¾ø½À´Ï´Ù.
     
    »ó¼¼¼³¸í »óÇ°Èıâ(0) »óÇ°¹®ÀÇ(0) ±³È¯ ¹× ¹ÝÇ°/¹è¼Û/°áÁ¦
    ¹øÈ£ Á¦¸ñ À̸§ ³¯Â¥
    ÀÛ¼ºµÈ »óÇ°¹®ÀÇ°¡ ¾ø½À´Ï´Ù.
      »óÇ°¹®ÀÇÇϱâ
    »ó¼¼¼³¸í »óÇ°Èıâ(0) »óÇ°¹®ÀÇ(0) ±³È¯ ¹× ¹ÝÇ°/¹è¼Û/°áÁ¦
    ¹ÝÇ°±³È¯
    ±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì
    - ±¸ÀÔÈÄ 7ÀÏ À̳»¿¡ µ¿ÀÏÁ¦Ç°À¸·Î ±³È¯ °¡´ÉÇÏ¸ç ¿î¼Ûºñ´Â ÆǸÅÀÚ ºÎ´ãÀÔ´Ï´Ù.
    - ´Ù¸¥ Á¦Ç°À¸·Î ±³È¯, ¶Ç´Â ÀÌ»óÀÌ ¾ø´Â Á¦Ç°°ú ÇÔ²² ±³È¯À» ¿øÇÏ½Ç °æ¿ì ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

    ±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì (»ö»ó,»çÀÌÁî,´Ù¸¥»óÇ°±³È¯)
    - ±¸ÀÔÈÄ 7ÀÏÀ̳» ±³È¯ °¡´ÉÇÏ¸ç ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

    !! ÁÖÀÇ»çÇ×
    ºñ´ÒÆ÷Àå ¹× TagÀÇ Æó±â ¶Ç´Â ÈÑ¼Õ µîÀ¸·Î »óÇ° °¡Ä¡°¡ ¸ê½ÇµÈ °æ¿ì¿¡´Â Á¦ÇÑ.
    ¹ÝÇ°½Ã¿¡ ÇØ´ç »çÀºÇ°ÀÌ ÀÖÀ» °æ¿ì °°ÀÌ º¸³»ÁÖ¼Å¾ß ÇÕ´Ï´Ù.
    ¹è¼Û¾È³»
    °áÁ¦ÈÄ 3~7ÀÏ À̳»¿¡ »óÇ°À» ¹Þ¾Æ º¸½Ç ¼ö ÀÖ½À´Ï´Ù.
    ±¹³» ÃÖ´ëÀÇ ¹°·ù»ç ¿»·Î¿ìĸÅù踦 ÅëÇÏ¿© ½Å¼ÓÇÏ°í ¾ÈÀüÇÏ°Ô ¹è¼ÛµË´Ï´Ù.
    ¸ðµç Á¦Ç°Àº ÂøºÒ ¹ß¼ÛµË´Ï´Ù. ´Ü 30¸¸¿ø ÀÌ»ó ±¸ÀԽà ¹«·á¹è¼ÛÀÔ´Ï´Ù.
    (Á¦ÁÖµµ¸¦ Æ÷ÇÔÇÑ µµ¼­,»ê°£Áö¿ªÀº Ç×°ø·á ¶Ç´Â µµ¼±·á°¡ Ãß°¡µË´Ï´Ù.)
    °áÁ¦¾È³»
    °áÁ¦¹æ¹ýÀº ½Å¿ëÄ«µå, ±¹¹Î/BC(ISP), ¹«ÅëÀåÀÔ±Ý, Àû¸³±ÝÀÌ ÀÖ½À´Ï´Ù.
    Á¤»óÀûÀÌÁö ¸øÇÑ °áÁ¦·Î ÀÎÇÑ ÁÖ¹®À¸·Î ÆÇ´ÜµÉ ¶§´Â ÀÓÀÇ·Î ¹è¼ÛÀÌ º¸·ùµÇ°Å³ª,ÁÖ¹®ÀÌ Ãë¼ÒµÉ ¼ö ÀÖ½À´Ï´Ù.
    »óÈ£ : (ÁÖ)¿¡ÀÌÄ¡¿ÍÀÌ»ê¾÷     ÁÖ¼Ò : ÀÎõ±¤¿ª½Ã °è¾ç±¸ ÁÖºÎÅä·Î413¹ø±æ32     ´ëÇ¥ÀÚ : ÇãÁ¾¼ø     »ç¾÷ÀÚµî·Ï¹øÈ£ : 121-86-02196 (Á¤º¸È®ÀÎ)
    Åë½ÅÆǸž÷½Å°í : Á¦2015-ÀÎõ°è¾ç-0634È£     ºÎ°¡Åë½Å»ç¾÷ÀÚ¹øÈ£ : 121-86-02196     °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : ±èÈñÁ¤     °³ÀÎÁ¤º¸º¸È£±â°£ : ȸ¿øÅ»Åð½Ã
    È£½ºÆü­ºñ½ºÁ¦°ø¾÷ü :