    ¼öÀº ¼öºÐ H2S ÃøÁ¤±â
    ½ÇÀç°¡°ÝÀ̾ƴմϴÙ
    ÆǸŰ¡°Ý °¡°Ý¹®ÀÇ
    Á¦Ç°ÄÚµå AMH-DUT
    ÁÖ¹®¼ö·®
    »ó¼¼¼³¸í »óÇ°Èıâ(0) »óÇ°¹®ÀÇ(0) ±³È¯ ¹× ¹ÝÇ°/¹è¼Û/°áÁ¦



    Portable Hg concentration in the air measuring instrument Model 431   
    ´ë±âÁß ¼öÀº ³óµµ ÃøÁ¤±â
    ultraprecision (0.013ug/m3) measuring instrument Model J 405




















    • Mercury Surveys and Soil Screening
    • Spill Response
    • Ensure Worker Safety
    • Research Projects for Stack, Flue and Natural Gas
    • Hazardous Waste Sites
    • Mercury Exclusion Tests
    • Monitor Disposal and Recycling of Fluorescent Lamps
    • Exhaust Duct Analysis

    Specificatio

    Resolution

    0.001 mg/m3    (405 0.013ug/m3)

    Detection Range

    0.003-0.999 mg/m3 (405 999 ug/m3)

    Precision

    5% Relative Standard Deviation at 0.100 mg/m3

    Accuracy

    ¡¾ 5% at 0.100 mg/m3

    Response Time

    13 s in Sample Mode; 4 s in Survey Mode

    Flow Rate

    750 cc/min

    Power Requirements

    100-120 V ~ 50/60 Hz, 1 A or 220-240 V ~ 50/60 Hz, 1 A

    Internal Battery Pack

    Rechargeable nickel-cadmium

    Environmental Range

    0-40 ¡ÆC, noncondensing, nonexplosive

    Interfaces

    RS-232 PC using JCI software

    Dimensions

    6" W x 13" L x 4" H

    Weight

    7 lb

    Warranty

    One year, factory parts and labor

    Certifications

    European Communities (CE) for 220-240 V~ model only

             




















     
     
     
    Àç·á³» ¼öºÐ ÇÔ·® ºÐ¼® ÀåÄ¡ Model Computrac 1000XL 2000XL 4000 XL
    2009ºÎÅÍ »õ·ÎÈ÷ Ãâ½ÃµÈ 4000 XL¼öºÐÃøÁ¤ ±â´Â 1000°ú 2000ÀÇ ±â´ÉÀ» º¸°­ÇÑ Á¦Ç°ÀÔ´Ï´Ù
     
    - ¾Æ·¡ ºñ±³Ç¥ ÂüÁ¶




    Water content measurement, solids content measurement , ash content measurement Model Max 5000
    MAX 5000 Specificatio
    Sample Size 200 mg to 100 g
    Resolution Moisture: 0.0001%; Balance: 0.0001g
    Moisture/Solids Range 0.1% to 99.9%
    Dry Weight Range 0-300%
    Results Display % Moisture, % Solids, % Ash or % Dry Weight
    Ending Criteria Predict (Auto or Manual), Rate, Time, Rate of Time or Reliability
    Heating Range 25 - 600¡ÆC, Set in 1¡ÆC increments and maintained to ¡¾1¡ÆC within the range of 50 - 300¡ÆC; ¡¾2¡ÆC within the range of 300 - 600¡ÆC
    Test Parameter Memory 250 Programs
    Program Identification Alphanumeric; programmable prompts for lot or product ID numbers
    Test Result Memory Data from last 1,000 tests and graphs from last 100 tests
    Statistical Calculation Mean, Standard Deviation, and Relative Standard Deviation
    Power Requirements 100-120V ~ 50/60 Hz, 1 amp (standby) or 8 amps (heat on)
    Interfaces RS-232 (9-pin standard); parallel printer (LPT - PC standard);
    RJ-45 (Ethernet)
    Dimensions 470mm L x 323mm W x 24mm H; 18.5" L x 12".5 W x 10" H
    Weight 13.6 kg; 30 lbs
    Warranty Two years, factory parts and labor (one year international)
    Certifications cULus; CE
    Accessories
    Multi-Point Temperature Calibration Module; Printer; Sample Basket; Validation Package; Step Down Power Transformer
     

     2010 New Version  -Jerome¢ç J605  Hydrogen Sulfide Analyzer - ppb & ppt level H2S Gas Analyser
     
    ÈÞ´ëÇü  H2S
    ÃÖÀú³óµµ 20 ppt (0.02 ppb)Á¤¹Ðµµ·Î ºÐ¼®
    ´ë±âÁß ¾ÇÃë ºÐ¼® ³ó¾÷ºÐ¾ç ³ó¾÷ ±â»ó Åä¾ç¿À¿° ºÐ¾ß
     
    Applications:
    • Leak Detection
    • Quality Control
    • Ambient Air Analysis
    • Accuracy Check for other Hydrogen Sulfide Monitors and Control Systems
    • Applied Research
    • Scrubber Efficiency Testing
    • Hydrogen Sulfide Source Detection
    • Control Room Corrosion Monitoring
    • Landfills
    • Agricultural Applications
    • Regulatory Compliance and Permitting
    Features:
    • Rugged and easy to operate
    • Battery powered sensor regeneration (requires external battery pack)
    • Auto date/time stamp
    • On board data logging 20,000 samples
    • Inherently stable gold film sensor
    • Pressure sensitive membrane switch operation
    • Rechargeable internal battery pack for portability
    • Wide detection range allows for multiple applications
    • Automatic LCD backlight during low light conditions
    • Survey mode for rapid source detection of hydrogen sulfide concentrations
    • Microprocessor ensures a linear response throughout the entire range of the sensor
    • 4-20 mA output for SCADA systems
    Additional Features:
    • No PC Software Required
    • 20,000 Data Points
    • Stores Date, Time and Locations
    • On-Board Data Logging
    • Optional USB interface for data transfer and printing capabilities
    • 18 Hour Battery Life
    • Detects H2S levels as low as 3 ppb
    • Fulfills EPA requirements
    Jerome¢ç J605 Specifications:
    Resolution 20 ppt in Range 0
    Detection Range 3 ppb -10 ppm
    Accuracy/Precision Range 0: ¡¾1 ppb at 5 ppb/10%RSD
    Range 0: ¡¾3 ppb at 50 ppb/5%RSD
    Range 1: ¡¾0.03 ppm at 0.5 ppm /5%RSD
    Range 2: ¡¾0.3 ppm at 5.0 ppm/5%RSD
    Response Time
    Manual Range Selection  
    Range 2 (1.0 to 10.0 ppm) 12 seconds
    Range 1 (0.10 to 1.0 ppm) 18 seconds
    Range 0 (3 to 100 ppb) 12 to 27 seconds
    Auto Range Mode 12 to 52 seconds
    Flow Rate 150 ml/min or 0.15 l/min
    Power Requirements 12V DC/power adapter
    Internal Battery Pack Rechargeable nickel metal hydride (NiMH)
    Environmental Range 0-40¡ÆC, noncondensing, nonexplosive
    Interface USB
    Dimensions 11" W x 6" L x 6.5" H/ 28 cm L x 16 cm W x 17 cm H
    Weight 5.4 lbs / 2.5 kg
    Warranty 1 year, factory parts and labor
    Certifications European Communities (CE) and TUV: UL 61010-1:2004 standard and CSA-C22.2 NO. 61010-1-04
    Options: Functional Test Module for instrument verification in the field
    • Maintenance Kit for routine maintenance and upkeep
    • Hard or Soft Field Carrying Cases for versatile handling and additional storage
    • Car Adapter, External Battery Pack
    ¹«´Ü¼öÁý¹× º¹À縦 ±ÝÇÕ´Ï´Ù .
    »óÇ°Á¤º¸°í½Ã
    Á¦Ç°¸í ¼öÀº ¼öºÐ H2S ÃøÁ¤±â
    ÆǸŰ¡°Ý °¡°Ý¹®ÀÇ
    °ü·Ã»óÇ°
        
    »ó¼¼¼³¸í »óÇ°Èıâ(0) »óÇ°¹®ÀÇ(0) ±³È¯ ¹× ¹ÝÇ°/¹è¼Û/°áÁ¦
    ¹øÈ£ Á¦¸ñ À̸§ º°Á¡ ³¯Â¥
    ¾ÆÁ÷ ÀÛ¼ºµÈ »óÇ°ÆòÀÌ ¾ø½À´Ï´Ù.
     
    »ó¼¼¼³¸í »óÇ°Èıâ(0) »óÇ°¹®ÀÇ(0) ±³È¯ ¹× ¹ÝÇ°/¹è¼Û/°áÁ¦
    ¹øÈ£ Á¦¸ñ À̸§ ³¯Â¥
    ÀÛ¼ºµÈ »óÇ°¹®ÀÇ°¡ ¾ø½À´Ï´Ù.
      »óÇ°¹®ÀÇÇϱâ
    »ó¼¼¼³¸í »óÇ°Èıâ(0) »óÇ°¹®ÀÇ(0) ±³È¯ ¹× ¹ÝÇ°/¹è¼Û/°áÁ¦
    ¹ÝÇ°±³È¯
    ±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì
    - ±¸ÀÔÈÄ 7ÀÏ À̳»¿¡ µ¿ÀÏÁ¦Ç°À¸·Î ±³È¯ °¡´ÉÇÏ¸ç ¿î¼Ûºñ´Â ÆǸÅÀÚ ºÎ´ãÀÔ´Ï´Ù.
    - ´Ù¸¥ Á¦Ç°À¸·Î ±³È¯, ¶Ç´Â ÀÌ»óÀÌ ¾ø´Â Á¦Ç°°ú ÇÔ²² ±³È¯À» ¿øÇÏ½Ç °æ¿ì ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

    ±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì (»ö»ó,»çÀÌÁî,´Ù¸¥»óÇ°±³È¯)
    - ±¸ÀÔÈÄ 7ÀÏÀ̳» ±³È¯ °¡´ÉÇÏ¸ç ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

    !! ÁÖÀÇ»çÇ×
    ºñ´ÒÆ÷Àå ¹× TagÀÇ Æó±â ¶Ç´Â ÈÑ¼Õ µîÀ¸·Î »óÇ° °¡Ä¡°¡ ¸ê½ÇµÈ °æ¿ì¿¡´Â Á¦ÇÑ.
    ¹ÝÇ°½Ã¿¡ ÇØ´ç »çÀºÇ°ÀÌ ÀÖÀ» °æ¿ì °°ÀÌ º¸³»ÁÖ¼Å¾ß ÇÕ´Ï´Ù.
    ¹è¼Û¾È³»
    °áÁ¦ÈÄ 3~7ÀÏ À̳»¿¡ »óÇ°À» ¹Þ¾Æ º¸½Ç ¼ö ÀÖ½À´Ï´Ù.
    ±¹³» ÃÖ´ëÀÇ ¹°·ù»ç ¿»·Î¿ìĸÅù踦 ÅëÇÏ¿© ½Å¼ÓÇÏ°í ¾ÈÀüÇÏ°Ô ¹è¼ÛµË´Ï´Ù.
    ¸ðµç Á¦Ç°Àº ÂøºÒ ¹ß¼ÛµË´Ï´Ù. ´Ü 30¸¸¿ø ÀÌ»ó ±¸ÀԽà ¹«·á¹è¼ÛÀÔ´Ï´Ù.
    (Á¦ÁÖµµ¸¦ Æ÷ÇÔÇÑ µµ¼­,»ê°£Áö¿ªÀº Ç×°ø·á ¶Ç´Â µµ¼±·á°¡ Ãß°¡µË´Ï´Ù.)
    °áÁ¦¾È³»
    °áÁ¦¹æ¹ýÀº ½Å¿ëÄ«µå, ±¹¹Î/BC(ISP), ¹«ÅëÀåÀÔ±Ý, Àû¸³±ÝÀÌ ÀÖ½À´Ï´Ù.
    Á¤»óÀûÀÌÁö ¸øÇÑ °áÁ¦·Î ÀÎÇÑ ÁÖ¹®À¸·Î ÆÇ´ÜµÉ ¶§´Â ÀÓÀÇ·Î ¹è¼ÛÀÌ º¸·ùµÇ°Å³ª,ÁÖ¹®ÀÌ Ãë¼ÒµÉ ¼ö ÀÖ½À´Ï´Ù.
    »óÈ£ : (ÁÖ)¿¡ÀÌÄ¡¿ÍÀÌ»ê¾÷     ÁÖ¼Ò : ÀÎõ±¤¿ª½Ã °è¾ç±¸ ÁÖºÎÅä·Î413¹ø±æ32     ´ëÇ¥ÀÚ : ÇãÁ¾¼ø     »ç¾÷ÀÚµî·Ï¹øÈ£ : 121-86-02196 (Á¤º¸È®ÀÎ)
    Åë½ÅÆǸž÷½Å°í : Á¦2015-ÀÎõ°è¾ç-0634È£     ºÎ°¡Åë½Å»ç¾÷ÀÚ¹øÈ£ : 121-86-02196     °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : ±èÈñÁ¤     °³ÀÎÁ¤º¸º¸È£±â°£ : ȸ¿øÅ»Åð½Ã
    È£½ºÆü­ºñ½ºÁ¦°ø¾÷ü :