- Compact and portable — only one case!
- Fast setup with modular components and quick-connect tubing
- Ideal for remote locations and indoor air sampling
- 24-hour Li-Ion battery-operated system
- Easy, secure operation from within a heavy-duty lockable case
- Quick-mount bracket is easy to install
- Quick-change battery packs
- Rain cover protects sampling head
- Compact for easy transport
- Low noise for indoors
- System pump provides constant, accurate airflows
- Simple 3-button keypad for setting a single unattended sample run
- Program for multiple runs with a PC and DataTrac for Leland Legacy Software
- Available for sampling PM10, PM2.5, or PAHs/PHDDs/PHDFs
Deployable Systems Performance Profile
Flow Rate |
10 L/min |
Run Time |
> 24 hrs (one battery charge) |
Power |
Rechargeable Li-Ion battery, 7.4 V, 12-Ah capacity, 88 Wh |
Case Dimensions |
18.5 x 14.1 x 6.9 in (47 x 36 x 18 cm) |
System Weight |
DPS: 13 lbs (5.9 kg)
DCS: 12.2 lbs (5.5 kg) |
À¯·®
|
10 L / ºÐ
|
½ÇÇà ½Ã°£
|
> 24 ½Ã°£ (ÇϳªÀÇ ¹èÅ͸® ÃæÀü)
|
Èû
|
ÃæÀü½Ä ¸®Æ¬ ÀÌ¿Â ¹èÅ͸®, 7.4 V, 12 ¾Æ ¿ë·®, 88 ¤±
|
ÄÉÀ̽º Å©±â
|
18.5 X 14.1ÀÇ X 6.9 (47 X 36 X 18cm)
|
½Ã½ºÅÛ ¹«°Ô
|
DPS : 13ÆÄ¿îµå (5.9 kg) DCS : 12.2 ÆÄ¿îµå (5.5 kg)
|
Description
|
Qty.
|
Cat. No.
|
DPS System includes sample pump with connection case, charger (100-240 V), IMPACT sampling head, 2 filter cassettes, calibration adapter, rain cover, 25 disposable impaction disks (limited shelf-life), filter cassette opener, tubing with quick-connect fitting, and mounting bracket in a heavy-duty lockable carry case. Two external battery assemblies with adapters are packaged separatelyDPS Systems contain Leland Legacy pumps with Li-Ion batteries and may be subject to special shipping regulations dependent upon quantity.Use in non-explosive environments only. Not UL Listed for intrinsic safety.Provides data similar to data from Federal Reference Method samplers. The DPS System is not a Federal Reference Method sampler.
|
PM10 Kit
|
ea
|
100-3901
|
PM2.5 Kit
|
ea
|
100-3903
|
Collection Filters for DPS System (not supplied with system)Select a collection filter based on your application; required for sampling
|
Qty.
|
Cat. No.
|
Quartz Filters, 47 mm, Tissuquartz, 432 µm thick
|
25
|
225-1823
|
PTFE (Teflon) Filters, 47 mm, 2.0-µm pore size, with PMP support ring Back pressure on PTFE (Teflon) filters can vary within the same lot. The maximum operating temperature is 464 F (240 C) based on PMP support ring.
|
50
|
225-1747
|
Accessories
|
Qty.
|
Cat. No.
|
Replacement Impaction Disks, 37 mm, pre-oiled, ready to use, disposable Required for sampling,limited shelf-life
|
25
|
225-395
|
50
|
225-395A
|
Replacement Filter Cassette
|
ea
|
225-396
|
Petri Dish Slide, for filter transport
|
100
|
225-2-01
|
DataTrac Software for Leland Legacy includes software on CD, DataTrac adapter, and DataTrac cable. Requires Windows 98 or higher and available serial port or USB to serial adapter compatible with the PC and system
|
ea
|
877-92
|
DCS Ordering Information
Description
|
Cat. No.
|
DCS System includes sample pump with connection case, charger (100-240 V), sampling head, calibration adapter, rain cover, sample tubing with quick-connect fitting, calibration tubing, and mounting bracket in a heavy-duty lockable carry case. Two external battery assemblies with adapters are packaged separately. Cartridges, filters, and media available separately
|
100-3960
|
DCS Cartridges, stainless steel, required for sampling; select based on application Require media below
|
Cat. No.
|
DCS Cartridge Marked for TO-9A, supplied in Teflon jar without media
|
226-200
|
DCS Cartridge Marked for TO-13A, supplied in Teflon jar without media
|
226-201
|
Media, required, select based on application
|
Cat. No.
|
PUF, (polyether type), 40-mm diameter, cleaned, includes 3 PUFs wrapped in foil and supplied in glass jar with lid
|
P226DCS
|
XAD-2 Sorbent, 100 gm, 20/60 mesh size, cleaned, supplied in glass jar with lid
|
P226201
|
XAD-2 Sorbent, 20 gm, 20/60 mesh size, cleaned, supplied in glass jar with lid
|
P226203
|
Quartz Filters, 47 mm, Qm-A, 100/pk
|
225-1811
|
Accessories
|
Cat. No.
|
DataTrac Software for Leland Legacy includes software on CD, DataTrac adapter, and DataTrac cable. Requires Windows 98 or higher and available serial port or USB to serial adapter compatible with the PC and system
|
877-92
|
¹«´Ü¼öÁý¹× º¹À縦 ±ÝÇÕ´Ï´Ù .
»óÇ°Á¤º¸°í½Ã
Á¦Ç°¸í |
DPS»ùÇøµ PM10, PM2.5 °ø±â »ùÇøµ ÆßÇÁ ¹èÆ÷ ¹Ì¸³ÀÚ »ùÇ÷¯ (DPS) ½Ã½ºÅÛ |
ÆǸŰ¡°Ý |
°¡°Ý¹®ÀÇ |
ºê·£µå |
GIZ |
¿ø»êÁö |
¿Ü»ê |
Á¦Á¶»ç |
wjsekdvh |
¹ÝÇ°±³È¯ |
±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì
- ±¸ÀÔÈÄ 7ÀÏ À̳»¿¡ µ¿ÀÏÁ¦Ç°À¸·Î ±³È¯ °¡´ÉÇÏ¸ç ¿î¼Ûºñ´Â ÆǸÅÀÚ ºÎ´ãÀÔ´Ï´Ù.
- ´Ù¸¥ Á¦Ç°À¸·Î ±³È¯, ¶Ç´Â ÀÌ»óÀÌ ¾ø´Â Á¦Ç°°ú ÇÔ²² ±³È¯À» ¿øÇÏ½Ç °æ¿ì ±¸¸ÅÀÚ²²¼ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.
±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì (»ö»ó,»çÀÌÁî,´Ù¸¥»óÇ°±³È¯)
- ±¸ÀÔÈÄ 7ÀÏÀ̳» ±³È¯ °¡´ÉÇÏ¸ç ±¸¸ÅÀÚ²²¼ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.
!! ÁÖÀÇ»çÇ×
ºñ´ÒÆ÷Àå ¹× TagÀÇ Æó±â ¶Ç´Â ÈÑ¼Õ µîÀ¸·Î »óÇ° °¡Ä¡°¡ ¸ê½ÇµÈ °æ¿ì¿¡´Â Á¦ÇÑ.
¹ÝÇ°½Ã¿¡ ÇØ´ç »çÀºÇ°ÀÌ ÀÖÀ» °æ¿ì °°ÀÌ º¸³»ÁÖ¼Å¾ß ÇÕ´Ï´Ù. |
¹è¼Û¾È³» |
°áÁ¦ÈÄ 3~7ÀÏ À̳»¿¡ »óÇ°À» ¹Þ¾Æ º¸½Ç ¼ö ÀÖ½À´Ï´Ù.
±¹³» ÃÖ´ëÀÇ ¹°·ù»ç ¿»·Î¿ìĸÅù踦 ÅëÇÏ¿© ½Å¼ÓÇÏ°í ¾ÈÀüÇÏ°Ô ¹è¼ÛµË´Ï´Ù.
¸ðµç Á¦Ç°Àº ÂøºÒ ¹ß¼ÛµË´Ï´Ù. ´Ü 30¸¸¿ø ÀÌ»ó ±¸ÀԽà ¹«·á¹è¼ÛÀÔ´Ï´Ù.
(Á¦ÁÖµµ¸¦ Æ÷ÇÔÇÑ µµ¼,»ê°£Áö¿ªÀº Ç×°ø·á ¶Ç´Â µµ¼±·á°¡ Ãß°¡µË´Ï´Ù.) |
°áÁ¦¾È³» |
°áÁ¦¹æ¹ýÀº ½Å¿ëÄ«µå, ±¹¹Î/BC(ISP), ¹«ÅëÀåÀÔ±Ý, Àû¸³±ÝÀÌ ÀÖ½À´Ï´Ù.
Á¤»óÀûÀÌÁö ¸øÇÑ °áÁ¦·Î ÀÎÇÑ ÁÖ¹®À¸·Î ÆÇ´ÜµÉ ¶§´Â ÀÓÀÇ·Î ¹è¼ÛÀÌ º¸·ùµÇ°Å³ª,ÁÖ¹®ÀÌ Ãë¼ÒµÉ ¼ö ÀÖ½À´Ï´Ù. |