    The Doble LDS-6 is a highly sophisticated digital measuring system for partial discharge detection and analysis.
    It is trusted as a valuable tool for factory and laboratory testing.

    The LDS-6 can be used to test a variety of high voltage apparatus.
    Use the LDS-6 to perform PD quality tests on motors, generators, transformers,
    MV and HV cable systems, switchgear and additional HV accessories.

    The LDS-6 complies with IEC 60270, VDE 0434 as well as various IEEE and other standards


  • Sensors  & Accessories

    Calibrators

    LDC-5 Calibrator

    LDC-5 Calibrator

    • For external calibration of the standard PD measuring circuit according to IEC 60270
    • Quantifying of the main PD quantity ¡°apparent charge¡±
    • Output for calibrating pulse charges: 5, 20, 100, 500 pC.
    LDC-5/D Calibrator

    LDC-5 /D Calibrator

    • Double impulse calibrator
    • For external calibration of the standard PD measuring circuit according to IEC 60270 (single pulses)
    • PD measurements on long cables and in accordance with standards requiring the verification of the double pulse behavior of the employed PD measuring system
    • Produces these standardized time parameters according to the IEC 855-3
    • Output for calibrating pulse charges (5, 20, 100, 500 pC)
    LDC-5_RIV

    LDC-5/RIV

    • External RIV calibrator for standardized PD measuring circuit according to IEC 60270
    • Quantifies ¡°apparent charge¡±
    • Magnitude of the calibrating pulses can be selected by the ¡°Charge Magnitude¡± switch
    LDC-5_S2

    LDC-5/S2

    • Charge injector designed for simulation of PD pulses, especially for on-site PD testing
    • Generates five different charge magnitudes, which appear at the 5 BNC-jacks
    • Calibrating charge can be fed into the terminals of test sample (according to IEC 60270 and DIN VDE 0434)

    Sensors & Accessories

    PDDC17-PD_COUPLER

    PDDC-17 PD Decoupler

    • For use with rotating machines
    • Designed for PD signal transmission with a bandwidth above 30 MHz at 50 Ohm matching resistance
    • PD decoupling unit with integrated PD measuring impedance for decoupling of PD pulses from the standard PD measuring circuit acc. to IEC 60270
    • Voltage signal for phase resolved measurements
    • Composite PD and voltage signal, additive superimposed
    PDDC24-FAILSAFEPD_COUPLER

    PDDC-24 Failsafe & LF Coupler

    • For use with rotating machines.
    • Designed for PD signal transmission with a bandwidth above 30 MHz at 50 Ohm matching resistance
    • Transmits test voltage signals at the same wire
    • PD decoupling unit with integrated PD measuring impedance for decoupling of PD pulses from the standard PD measuring circuit according to IEC 60270
    • Voltage signal for phase resolved measurements
    • Composite PD and voltage signal, additive superimposed
    • Integrated high-voltage fuse
    BC Matching Unit

    BC Matching Unit

    • For use with rotating machines
    • Works with your previously installed couplers for PD testing in rotating machines
    • Designed to adapt conventional PD measuring methods to the 80pF-Line coupler
    • Improves signals from existing couplers
    • Avoids outages that would be needed to replace high frequency couplers with low frequency couplers
    LDM-5_SP1_Splitting_Box

    LDM-5/SP1

    • For use with PDDC range
    • Splitting box designed for PD/TV-signal transmission
    • Compact device with all input and output lines at the sides
    • Includes fast overvoltage protection to help prevent dangerous overvoltage due to unexpected breakdown of the test sample
    CONNECTION_BOX

    Connection Boxes

    • For use with LDM-5/U5
    • Connection Boxes are designed for PD/TV-signal transmission and diplexing
    • Two and three channel connection box options
    HFCT300sensor 2207403000002

    HFCT-300 Sensor

    • For use at cable terminations
    • Hand-held split-core sensor specially designed for coupling out high frequency PD-signals
    • Applicable for PD tests on any part of the PD signal loop between the insulation electrodes where the outgoing and incoming signals do not cancel each other out
    • For highly sensitive PD measurements with superposed line currents or high reactive currents (50/60 Hz) which can reach up to 300 A
    30dB UHF Sensor Pre-Amplifier

    Sensor Pre-Amplifier

    • For use with all kind of UHF sensors
    • High sensitivity and high gain sensor amplifier
    • Special protection circuitry protects the input against excessive input power
    • Integrated soft start reduces the maximum peak current when powering up

    Measuring Impedances

    LDM-5_U5

    LDM-5/U5

    • For cable and transformer testing
    • General use measuring impedance designed for the decoupling of the PD current pulses on the PD coupling capacitor, changing in equivalent voltage pulses and forwarding to the PD detector (according to IEC 60270)
    • Voltage signal for phase-resolved measurements by an internal low voltage capacitor for measuring test voltage and forwarding to PD test equipment
    • Output for test voltage value, derived from the coupling capacitor
    • No additional HV divider capacitor is necessary
    • With up to 2 switches for maximum 4 different coupling capacitances
    LDM-5U_RIV

    LDM-5/U-RIV

    • For transformer testing
    • Designed for the decoupling of the PD current pulses on the PD coupling capacitor, changing in equivalent voltage pulses and forwarding to the PD detector (according to IEC 60270)
    • Connects to a bushing tap or a coupling capacitor
    • Low voltage capacitor for measuring test voltage and forwarding to PD test equipment
    • Voltage signal for phase-resolved measurements
    • Output for test voltage value, derived from the coupling capacitor
    • No additional HV divider capacitor is necessary

    LDF-6/FU

    • To be used with LDM-5/U5
    • Band pass filter designed to improve electromagnetic compatibility in the measuring surroundings
    • Reduction of the disturbing influence of high frequency currents
    • Use between a measuring impedance and PD device
    CC1000-60

    Coupling Capacitors

    • To be used with LDM-5/U5
    • The coupling capacitor connects the high voltage with the PD-measuring device
    • Mobile and equipped with the suitable security procedures
    • Capacitance 1 nF
      • CC1000/60: Rated Voltage 60 kV
      • CC1000/120: Rated Voltage 120 kV
    • Capacitance 10 nF
      • CC10000/50: Rated Voltage 50 kV.
    LDM-6_3

    LDM-6/3

    • To be used with Coupling Capacitors
    • Designed for the decoupling of the PD current pulses on the PD coupling capacitor, changing in equivalent voltage pulses and forwarding to the PD detector (according to IEC 60270)
    • Voltage signal for phase-resolved measurements by an internal low voltage capacitor for measuring test voltage and forwarding to PD test equipment
    • Voltages decoupled from the bushing tap together with the PD signal
    • One signal output (TNC-socket) for voltage signal with added PD signal
    LDM-5_M6

    LDM-5/M8 Switching Box

    • For use with specially designed LDS-6 control software
    • Signal switch, specially designed for PD applications
    • Stores all measured PD data for each channel separately (8 measuring files)
    • Can customize a test procedure (test time, sequence of activation of the measuring impedances)

     

  • ¹«´Ü¼öÁý¹× º¹À縦 ±ÝÇÕ´Ï´Ù .
    »óÇ°Á¤º¸°í½Ã
    Á¦Ç°¸í LDS-6 ºÎºÐ¹æÀüÁø´Ü½Ã½ºÅÛ(for IEC60270 Standards) IEC 60270, VDE 0434 Ç¥ÁØÁؼö
    ÆǸŰ¡°Ý °¡°Ý¹®ÀÇ
    ºê·£µå DOBLE
    Á¦Á¶»ç DOBLE
    °ü·Ã»óÇ°
        
    »ó¼¼¼³¸í »óÇ°Èıâ(0) »óÇ°¹®ÀÇ(0) ±³È¯ ¹× ¹ÝÇ°/¹è¼Û/°áÁ¦
    ¹øÈ£ Á¦¸ñ À̸§ º°Á¡ ³¯Â¥
    ¾ÆÁ÷ ÀÛ¼ºµÈ »óÇ°ÆòÀÌ ¾ø½À´Ï´Ù.
     
    »ó¼¼¼³¸í »óÇ°Èıâ(0) »óÇ°¹®ÀÇ(0) ±³È¯ ¹× ¹ÝÇ°/¹è¼Û/°áÁ¦
    ¹øÈ£ Á¦¸ñ À̸§ ³¯Â¥
    ÀÛ¼ºµÈ »óÇ°¹®ÀÇ°¡ ¾ø½À´Ï´Ù.
      »óÇ°¹®ÀÇÇϱâ
    »ó¼¼¼³¸í »óÇ°Èıâ(0) »óÇ°¹®ÀÇ(0) ±³È¯ ¹× ¹ÝÇ°/¹è¼Û/°áÁ¦
    ¹ÝÇ°±³È¯
    ±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì
    - ±¸ÀÔÈÄ 7ÀÏ À̳»¿¡ µ¿ÀÏÁ¦Ç°À¸·Î ±³È¯ °¡´ÉÇÏ¸ç ¿î¼Ûºñ´Â ÆǸÅÀÚ ºÎ´ãÀÔ´Ï´Ù.
    - ´Ù¸¥ Á¦Ç°À¸·Î ±³È¯, ¶Ç´Â ÀÌ»óÀÌ ¾ø´Â Á¦Ç°°ú ÇÔ²² ±³È¯À» ¿øÇÏ½Ç °æ¿ì ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

    ±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì (»ö»ó,»çÀÌÁî,´Ù¸¥»óÇ°±³È¯)
    - ±¸ÀÔÈÄ 7ÀÏÀ̳» ±³È¯ °¡´ÉÇÏ¸ç ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

    !! ÁÖÀÇ»çÇ×
    ºñ´ÒÆ÷Àå ¹× TagÀÇ Æó±â ¶Ç´Â ÈÑ¼Õ µîÀ¸·Î »óÇ° °¡Ä¡°¡ ¸ê½ÇµÈ °æ¿ì¿¡´Â Á¦ÇÑ.
    ¹ÝÇ°½Ã¿¡ ÇØ´ç »çÀºÇ°ÀÌ ÀÖÀ» °æ¿ì °°ÀÌ º¸³»ÁÖ¼Å¾ß ÇÕ´Ï´Ù.
    ¹è¼Û¾È³»
    °áÁ¦ÈÄ 3~7ÀÏ À̳»¿¡ »óÇ°À» ¹Þ¾Æ º¸½Ç ¼ö ÀÖ½À´Ï´Ù.
    ±¹³» ÃÖ´ëÀÇ ¹°·ù»ç ¿»·Î¿ìĸÅù踦 ÅëÇÏ¿© ½Å¼ÓÇÏ°í ¾ÈÀüÇÏ°Ô ¹è¼ÛµË´Ï´Ù.
    ¸ðµç Á¦Ç°Àº ÂøºÒ ¹ß¼ÛµË´Ï´Ù. ´Ü 30¸¸¿ø ÀÌ»ó ±¸ÀԽà ¹«·á¹è¼ÛÀÔ´Ï´Ù.
    (Á¦ÁÖµµ¸¦ Æ÷ÇÔÇÑ µµ¼­,»ê°£Áö¿ªÀº Ç×°ø·á ¶Ç´Â µµ¼±·á°¡ Ãß°¡µË´Ï´Ù.)
    °áÁ¦¾È³»
    °áÁ¦¹æ¹ýÀº ½Å¿ëÄ«µå, ±¹¹Î/BC(ISP), ¹«ÅëÀåÀÔ±Ý, Àû¸³±ÝÀÌ ÀÖ½À´Ï´Ù.
    Á¤»óÀûÀÌÁö ¸øÇÑ °áÁ¦·Î ÀÎÇÑ ÁÖ¹®À¸·Î ÆÇ´ÜµÉ ¶§´Â ÀÓÀÇ·Î ¹è¼ÛÀÌ º¸·ùµÇ°Å³ª,ÁÖ¹®ÀÌ Ãë¼ÒµÉ ¼ö ÀÖ½À´Ï´Ù.
    »óÈ£ : (ÁÖ)¿¡ÀÌÄ¡¿ÍÀÌ»ê¾÷     ÁÖ¼Ò : ÀÎõ±¤¿ª½Ã °è¾ç±¸ ÁÖºÎÅä·Î413¹ø±æ32     ´ëÇ¥ÀÚ : ÇãÁ¾¼ø     »ç¾÷ÀÚµî·Ï¹øÈ£ : 121-86-02196 (Á¤º¸È®ÀÎ)
    Åë½ÅÆǸž÷½Å°í : Á¦2015-ÀÎõ°è¾ç-0634È£     ºÎ°¡Åë½Å»ç¾÷ÀÚ¹øÈ£ : 121-86-02196     °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : ±èÈñÁ¤     °³ÀÎÁ¤º¸º¸È£±â°£ : ȸ¿øÅ»Åð½Ã
    È£½ºÆü­ºñ½ºÁ¦°ø¾÷ü :