Portable Ethylene Gas Analyzer Field Kit (CI-900FK)
The CI-900FK, C2H4 gas analyzer provides accurate, real-time measurement of ethylene gas concentrations, in a compact package suitable for field and laboratory use. At the core of the instrument, the CI-900 uses an electrochemical sensor technology that offers extraordinary sensitivity to ethylene, with accurate readings as low as 10 ppbv in air.
Ethylene, a plant hormone produced in response to stress, ripening or maturity has been a useful agricultural diagnostic indicator for many decades. Traditionally, trace ethylene gas measurements were available only to those users, primarily laboratory researchers, who had access to gas chromatography or similar technologies. The CI-900 has been designed for in vivo studies conducted by field and laboratory researchers as well as post harvest cold storage facility operators who require trace C2H4 gas detection capability.
- The new CI-900 sets the industry standard for precision measurements of ethylene
- Non-destructive measurement
- The CI-900 is 183.5mm x 111mm x 120mm and weighs just 2.43 Kilograms
Features
- High C2H4 sensitivity down to 1 ppb
- CO2 and C4H6 sensing capability (optional)
- Compact and portable form factor (2.43 Kg)
- Real-time, continuous monitoring
- Internal data logging and storage (4GB SD card)
- User adjustable sampling rate
- Transflective display enables easy viewing in direct sunlight
- Rechargeable Li-Ion battery provides 4 hours of uninterrupted field use
CH4 and C4H6 Sensor Specifications |
Sensor Type: |
Electrochemical |
Air Sampling Rate: |
0.4 liters/min |
Sampling: |
Closed-loop < 3min / Open loop monitoring @ 5sec interval |
Nominal Range: |
0 - 10ppm |
Resolution: |
1ppb |
Accuracy: |
¡¾ 5% adjusted for temperature and humidity |
Display: |
Sunlight visible transflective graphic LCD |
Operating Environment: |
5¡ÆC - 45¡ÆC (10-90% humidity non-condensing) |
Battery Capacity: |
4 Hours - rechargeable Li-Ion (5000mAh) |
Dimensions: |
183.5mm x 111mm x 120mm |
Weight: |
2.43 Kg |
Enclosure: |
Anodized aluminum |
Warm-up Time: |
<5 minutes |
|
|
CO2 Sensor Specifications |
Sensor Type: |
Low power Non-Dispersive Infrared Gas Analyzer |
Chopping Frequency: |
1Hz |
Source Life: |
5000 hours |
Measuring Range: |
0 to 2000 ppm (Standard) - 0 to 3000 ppm (Optional) |
Resolution: |
0.1 ppm |
Repeatability: |
¡¾0.1 ppm (short term) |
Accuracy: |
< ¡¾ 2% up to 3000 ppm |
Sample cell: |
100 mm x 10.2 mm (3.94" L x 0.40" Dia) |
Warm-up Time: |
<3 minutes |
¹«´Ü¼öÁý¹× º¹À縦 ±ÝÇÕ´Ï´Ù .
»óÇ°Á¤º¸°í½Ã
Á¦Ç°¸í |
¿¡Æ¿·» °¡½º ºÐ¼®±â , CI-900 , ¿¡Æ¿·» °¡½º ºÐ¼®±â |
ÆǸŰ¡°Ý |
31,200,000¿ø |
ºê·£µå |
CID |
¿ø»êÁö |
USA |
Á¦Á¶»ç |
CID |
¹ÝÇ°±³È¯ |
±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì
- ±¸ÀÔÈÄ 7ÀÏ À̳»¿¡ µ¿ÀÏÁ¦Ç°À¸·Î ±³È¯ °¡´ÉÇÏ¸ç ¿î¼Ûºñ´Â ÆǸÅÀÚ ºÎ´ãÀÔ´Ï´Ù.
- ´Ù¸¥ Á¦Ç°À¸·Î ±³È¯, ¶Ç´Â ÀÌ»óÀÌ ¾ø´Â Á¦Ç°°ú ÇÔ²² ±³È¯À» ¿øÇÏ½Ç °æ¿ì ±¸¸ÅÀÚ²²¼ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.
±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì (»ö»ó,»çÀÌÁî,´Ù¸¥»óÇ°±³È¯)
- ±¸ÀÔÈÄ 7ÀÏÀ̳» ±³È¯ °¡´ÉÇÏ¸ç ±¸¸ÅÀÚ²²¼ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.
!! ÁÖÀÇ»çÇ×
ºñ´ÒÆ÷Àå ¹× TagÀÇ Æó±â ¶Ç´Â ÈÑ¼Õ µîÀ¸·Î »óÇ° °¡Ä¡°¡ ¸ê½ÇµÈ °æ¿ì¿¡´Â Á¦ÇÑ.
¹ÝÇ°½Ã¿¡ ÇØ´ç »çÀºÇ°ÀÌ ÀÖÀ» °æ¿ì °°ÀÌ º¸³»ÁÖ¼Å¾ß ÇÕ´Ï´Ù. |
¹è¼Û¾È³» |
°áÁ¦ÈÄ 3~7ÀÏ À̳»¿¡ »óÇ°À» ¹Þ¾Æ º¸½Ç ¼ö ÀÖ½À´Ï´Ù.
±¹³» ÃÖ´ëÀÇ ¹°·ù»ç ¿»·Î¿ìĸÅù踦 ÅëÇÏ¿© ½Å¼ÓÇÏ°í ¾ÈÀüÇÏ°Ô ¹è¼ÛµË´Ï´Ù.
¸ðµç Á¦Ç°Àº ÂøºÒ ¹ß¼ÛµË´Ï´Ù. ´Ü 30¸¸¿ø ÀÌ»ó ±¸ÀԽà ¹«·á¹è¼ÛÀÔ´Ï´Ù.
(Á¦ÁÖµµ¸¦ Æ÷ÇÔÇÑ µµ¼,»ê°£Áö¿ªÀº Ç×°ø·á ¶Ç´Â µµ¼±·á°¡ Ãß°¡µË´Ï´Ù.) |
°áÁ¦¾È³» |
°áÁ¦¹æ¹ýÀº ½Å¿ëÄ«µå, ±¹¹Î/BC(ISP), ¹«ÅëÀåÀÔ±Ý, Àû¸³±ÝÀÌ ÀÖ½À´Ï´Ù.
Á¤»óÀûÀÌÁö ¸øÇÑ °áÁ¦·Î ÀÎÇÑ ÁÖ¹®À¸·Î ÆÇ´ÜµÉ ¶§´Â ÀÓÀÇ·Î ¹è¼ÛÀÌ º¸·ùµÇ°Å³ª,ÁÖ¹®ÀÌ Ãë¼ÒµÉ ¼ö ÀÖ½À´Ï´Ù. |