¿À´Ã º» »óÇ° (0)
    no
    show
    °ßÀû¹®ÀÇ
    ½Ç½Ã°£°ßÀû
    ±â¼úÀÚ·á½Ç
    °øÁö»çÇ×
    Áú¹®°ú ´äº¯
    °í°´¼¾ÅÍ
    T.032-571-0094/0093
    ¿ù - ±Ý : 09:00 ~ 18:00
    Á¡½É : 12:00 ~ 13:00
    Åä, ÀÏ, °øÈÞÀÏ ÈÞ¹«
    °í°´¼¾ÅÍ ¿¬°áÀÌ Àß µÇÁö¾ÊÀ»½Ã
    Q&A °Ô½ÃÆÇÀ» ÀÌ¿ëÇØÁÖ¼¼¿ä.

    Rudolph ±¼Àý°è (J357 Automatic Refractometer)
    Á¦¾à, È­ÇÐ, ¼®À¯, ¿¡¼¾¼È ¿ÀÀÏ, Çâ¼ö ¹× È­ÀåÇ° ±¼Àý°è»ç¿ë
    ÆǸŰ¡°Ý 22,000,000¿ø
    ¿ø»êÁö USA
    ºê·£µå Rudolph
    Á¦Á¶»ç Rudolph (·çµ¹ÇÁ)
    Á¦Ç°ÄÚµå J357
    ÁÖ¹®¼ö·®
    »ó¼¼¼³¸í »óÇ°Èıâ(0) »óÇ°¹®ÀÇ(0) ±³È¯ ¹× ¹ÝÇ°/¹è¼Û/°áÁ¦




     


    Rudolph J357 Refractometer offers highest performance for research labs.

    Designed as a research quality instrument the Rudolph J357 Digital, Bench-top Refractometer has the highest performance
    of any refractometer in the Rudolph range. This instrument offers the same extra wide RI measurement range as our chemical industry
     refractometer models
     combined with the high accuracy of our food industry refractometer models. It also offers the most powerful automatic
    temperature control (heating and cooling) and is able to make RI and BRIX measurements at up to 120 ¡ÆC. The J357 is a perfect choice for the
     most demanding pharmaceutical, chemical, petroleum, essential oils, fragrance and cosmetic refractometer users.

    Operation

    Operating the J357 is as simple as placing a sample on the artificial sapphire prism, closing the presser and reading the answer
    on the Digital Display — all in just a few seconds. There are no shadow lines to match and there is no eyepiece requiring any kind of operator determination
    or manual adjustment, the J357 is a fully Automatic Refractometer.. When the ¡°measure when stable mode¡± is selected, the J357 Refractometer automatically
     waits until the sample has been heated or cooled to a predefined temperature before initiating a measurement.

    Dual Electronic Temperature Control to 120 ¡ÆC

    Unlike other temperature controlled refractometers, the J357 has temperature control from both above and below the sample. The sample
    cover is controlled to the same temperature as the prism and, when lowered, is designed to provide a temperature controlled micro environment that
     provides unrivaled temperature stability, fast measurement time and minimal evaporation. With the Auto Measure option, the sample cover can also be used to initiate measurement.

    Optional Sample Presser

    The Rudolph J357 is available with an optional Temperature Controlled Sample Presser that touches the sample. Compared with the standard temperature
    controlled cover, the optional presser reduces the empty volume of the measurement area thereby decreasing evaporation and at the same time helping to
    evenly spread semi solid materials over the measurement prism. This feature offers improved performance on many samples.

    Calibration

    The J357 offers 1 point, 2 point or a full multi-point calibration. Calibration can be done at 20¡ÆC, 25¡ÆC or any user selectable temperature within the available
    range. Regardless of how many times the refractometer has been calibrated, it can always be restored to the initial factory calibration if required.

    Custom Scales

    The J357 Refractometer is available with 100 possible programmable scales. Custom scales can be set up in a few minutes. Simply enter 2, 6 or 10 data points
    of concentration and corresponding RI (refractive index) value, press Compute and the instrument creates a new custom scale.

    High Durability Sapphire Prism

    The J series refractometer offers a sapphire prism for high mechanical and chemical durability. The sample well is acid resistant 316 stainless steel with a Techtron 
    sealing ring. There is no lamp to change, the LED light source is guaranteed for 1,000,000 measurements.






    No matter how good a refractometer is, accurate results will only be obtained if the instrument is clean.
    The Rudolph J Series offers a flat, easy to clean prism that makes this process simple even with sticky
     samples like sugars, syrups, and petrochemicals.

    Built In 21 CFR Part 11 Compliant Data Storage

    Rudolph¡¯s J357 refractometer is available with data storage on a removable media card. In 21
     CFR mode the data storage system provides a secure password system for storing raw data to
    comply with FDA specifications. When using non 21 CFR 11 mode the data storage system is a
    powerful tool for kinetics experiments and excellent system for QA traceability and to help
     laboratories meet the requirements of ISO and similar quality systems.

    Interface

    A large 7.5cm x 10cm cold cathode florescent back lit graphics, digital LCD allows the scale, sample
     temperature, set temperature, air temperature, time, date and temperature correction status to be
    easily viewed. All functions are activated through a touchscreen panel which will not wear out or be
    misplaced like traditional or detachable keypads. The digital touchscreen is resistant to
     fingernails, sharp objects, chemicals, and acids.

    No Water Bath Needed


    Having Rudolph¡¯s J357 fully automatic electronic temperature control means:

    • A significant savings on bench space because the water bath is eliminated.
    • Integrated temperature control where the instrument knows when to measure and records both the Refractive Index measurement and the temperature.
    • Hot liquid from a bath can present a significant danger in the laboratory in the event of a split hose, the J357 doesn¡¯t use liquid and thereby eliminates this risk.
    • Eliminating the water bath removes the most maintenance intensive part of a Refractometer. Water baths need to be regularly filled, dosed with algaecide and cleaned.

    Traceability & 21 CFR Part 11 Compliance

    • All measurements are made automatically, which eliminates the need for operator judgment.
    • Calibration with fluids traceable to NIST and calibration data securely stored and available for review.
    • Temperature can be calibrated against a traceable thermometer.
    • Operator Traceability, full 21 CFR Part 11 compliant password system.
    • Verification step with electronic signature.

    Permanent Record of All Measurements

    In 21 CFR Part 11 mode, all measurements are written to a secure data storage card. Who used the instrument,
    what they measured and when it was measured is permanently stored on a locked storage media. The media card can also be used to transfer records to a
    computer for redundancy or ¡°backup¡± purposes.


    Suitable for a Range of High Demand Environments

    • Petroleum and Petrochemical Laboratories where the J357¡Çs ability to measure at up to 100¨¬C without a water bath makes the instrument ideal for ASTM D1218, D1747 and D5006.
    • Research Laboratories where the wide range and high accuracy of the Rudolph J357 means researchers have the maximum chance of measuring newly synthesized products.
    • Central Research and Reference Laboratories where having the most accurate results available for setting standards for an organization or a country is needed.
    • Chemical Laboratories can measure more viscous products with a level of accuracy previously available only in narrow range food instruments.

      J357 AUTOMATIC Specifications

      Measurement Scales Refractive Index (RI) 
      BRIX (% sucrose) 
      Temperature Corrected BRIX 
      Temperature Corrected RI 
      10 User Programmable Scales
      Measurement Range 1.29 - 1.70 RI,
      0 - 95 BRIX
      Resolution 0.00001 RI 
      0.01 BRIX
      Reproducibility ¡¾0.00002 RI, 
      ¡¾0.0l5 BRIX
      Accuracy ¡¾0.00004 RI, 
      Better than ¡¾0.03 BRIX
      Optical Wavelength 589.3nm
      Prism Artificial Sapphire
      Light Source Light Emitting Diode (est. life: >100,000 hrs.)
      Response Time Continuous readout or user programmable delay (i.e. a 25¨¬C sample can be cooled to 20¨¬C and measured in 20 seconds)
      Communication Interface Two RS232 ports 
      One parallel printer port 
      One auxiliary port
      Analog Control 0-10 volts, 4-20 mA
      Temp. Control Range 15¨¬C - 100¨¬C
      Temp. Sensor Accuracy ¡¾0.03¨¬C
      Ambient Temp. Limit 10¨¬C - 40¨¬C
      Temp. Correction Range 18¨¬C - 40¨¬C (for pure sucrose solutions)
      Temp. Measurement & Control Prism surface and presser
      Calibration 1, 2 or full multi-point calibration
      Operating Dimensions L: 15.75"  W: 13.5"  H: 6"  / 20 lbs.
      Shipping Dimensions L: 26"  W: 21"  H: 16" / 30 lbs.
      Power Requirements 100-240 volts, 50 Hz - 60 Hz
    ¹«´Ü¼öÁý¹× º¹À縦 ±ÝÇÕ´Ï´Ù .
    »óÇ°Á¤º¸°í½Ã
    Á¦Ç°¸í Rudolph ±¼Àý°è (J357 Automatic Refractometer)
    ÆǸŰ¡°Ý 22,000,000¿ø
    ºê·£µå Rudolph
    ¿ø»êÁö USA
    Á¦Á¶»ç Rudolph (·çµ¹ÇÁ)
    °ü·Ã»óÇ°
        
    »ó¼¼¼³¸í »óÇ°Èıâ(0) »óÇ°¹®ÀÇ(0) ±³È¯ ¹× ¹ÝÇ°/¹è¼Û/°áÁ¦
    ¹øÈ£ Á¦¸ñ À̸§ º°Á¡ ³¯Â¥
    ¾ÆÁ÷ ÀÛ¼ºµÈ »óÇ°ÆòÀÌ ¾ø½À´Ï´Ù.
     
    »ó¼¼¼³¸í »óÇ°Èıâ(0) »óÇ°¹®ÀÇ(0) ±³È¯ ¹× ¹ÝÇ°/¹è¼Û/°áÁ¦
    ¹øÈ£ Á¦¸ñ À̸§ ³¯Â¥
    ÀÛ¼ºµÈ »óÇ°¹®ÀÇ°¡ ¾ø½À´Ï´Ù.
      »óÇ°¹®ÀÇÇϱâ
    »ó¼¼¼³¸í »óÇ°Èıâ(0) »óÇ°¹®ÀÇ(0) ±³È¯ ¹× ¹ÝÇ°/¹è¼Û/°áÁ¦
    ¹ÝÇ°±³È¯
    ±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì
    - ±¸ÀÔÈÄ 7ÀÏ À̳»¿¡ µ¿ÀÏÁ¦Ç°À¸·Î ±³È¯ °¡´ÉÇÏ¸ç ¿î¼Ûºñ´Â ÆǸÅÀÚ ºÎ´ãÀÔ´Ï´Ù.
    - ´Ù¸¥ Á¦Ç°À¸·Î ±³È¯, ¶Ç´Â ÀÌ»óÀÌ ¾ø´Â Á¦Ç°°ú ÇÔ²² ±³È¯À» ¿øÇÏ½Ç °æ¿ì ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

    ±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì (»ö»ó,»çÀÌÁî,´Ù¸¥»óÇ°±³È¯)
    - ±¸ÀÔÈÄ 7ÀÏÀ̳» ±³È¯ °¡´ÉÇÏ¸ç ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

    !! ÁÖÀÇ»çÇ×
    ºñ´ÒÆ÷Àå ¹× TagÀÇ Æó±â ¶Ç´Â ÈÑ¼Õ µîÀ¸·Î »óÇ° °¡Ä¡°¡ ¸ê½ÇµÈ °æ¿ì¿¡´Â Á¦ÇÑ.
    ¹ÝÇ°½Ã¿¡ ÇØ´ç »çÀºÇ°ÀÌ ÀÖÀ» °æ¿ì °°ÀÌ º¸³»ÁÖ¼Å¾ß ÇÕ´Ï´Ù.
    ¹è¼Û¾È³»
    °áÁ¦ÈÄ 3~7ÀÏ À̳»¿¡ »óÇ°À» ¹Þ¾Æ º¸½Ç ¼ö ÀÖ½À´Ï´Ù.
    ±¹³» ÃÖ´ëÀÇ ¹°·ù»ç ¿»·Î¿ìĸÅù踦 ÅëÇÏ¿© ½Å¼ÓÇÏ°í ¾ÈÀüÇÏ°Ô ¹è¼ÛµË´Ï´Ù.
    ¸ðµç Á¦Ç°Àº ÂøºÒ ¹ß¼ÛµË´Ï´Ù. ´Ü 30¸¸¿ø ÀÌ»ó ±¸ÀԽà ¹«·á¹è¼ÛÀÔ´Ï´Ù.
    (Á¦ÁÖµµ¸¦ Æ÷ÇÔÇÑ µµ¼­,»ê°£Áö¿ªÀº Ç×°ø·á ¶Ç´Â µµ¼±·á°¡ Ãß°¡µË´Ï´Ù.)
    °áÁ¦¾È³»
    °áÁ¦¹æ¹ýÀº ½Å¿ëÄ«µå, ±¹¹Î/BC(ISP), ¹«ÅëÀåÀÔ±Ý, Àû¸³±ÝÀÌ ÀÖ½À´Ï´Ù.
    Á¤»óÀûÀÌÁö ¸øÇÑ °áÁ¦·Î ÀÎÇÑ ÁÖ¹®À¸·Î ÆÇ´ÜµÉ ¶§´Â ÀÓÀÇ·Î ¹è¼ÛÀÌ º¸·ùµÇ°Å³ª,ÁÖ¹®ÀÌ Ãë¼ÒµÉ ¼ö ÀÖ½À´Ï´Ù.
    »óÈ£ : (ÁÖ)¿¡ÀÌÄ¡¿ÍÀÌ»ê¾÷     ÁÖ¼Ò : ÀÎõ±¤¿ª½Ã °è¾ç±¸ ÁÖºÎÅä·Î413¹ø±æ32     ´ëÇ¥ÀÚ : ÇãÁ¾¼ø     »ç¾÷ÀÚµî·Ï¹øÈ£ : 121-86-02196 (Á¤º¸È®ÀÎ)
    Åë½ÅÆǸž÷½Å°í : Á¦2015-ÀÎõ°è¾ç-0634È£     ºÎ°¡Åë½Å»ç¾÷ÀÚ¹øÈ£ : 121-86-02196     °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : ±èÈñÁ¤     °³ÀÎÁ¤º¸º¸È£±â°£ : ȸ¿øÅ»Åð½Ã
    È£½ºÆü­ºñ½ºÁ¦°ø¾÷ü :