    ÀüÀڷεå, ÇÁ·Î±×·¡¸ÓºíDCÀÏ·ºÆ®·Î´Ð·Îµå, 3722A
    200W(200V/20A) Programmable DC Electronic Load
    ÆǸŰ¡°Ý 946,000¿ø
    ºê·£µå ARRAY
    Á¦Á¶»ç ARRAY
    Á¦Ç°ÄÚµå 3722A
    ÁÖ¹®¼ö·®
    »ó¼¼¼³¸í »óÇ°Èıâ(0) »óÇ°¹®ÀÇ(0) ±³È¯ ¹× ¹ÝÇ°/¹è¼Û/°áÁ¦



     

    ARRAY 372X īŸ·Î±× º¸±â



    ¼Ò °³


    372X ½Ã¸®Áî ÀüÀÚ ºÎÇÏ´Â Àü¿ø ¼Ò½º¸¦ Å×½ºÆ®ÇؾßÇÏ´Â ¸ðµç °÷¿¡¼­ ÀûÀÀ °¡´ÉÇÏ°í ±â´ÉÀûÀÎ ÀÚ»êÀ» Á¦°øÇÕ´Ï´Ù.
    ÀÌ ÀåÄ¡´Â ³ôÀº ½Å·Ú¼º, ¶Ù¾î³­ ¼º´É ¹× ´Ù¾çÇÑ ±â´ÉÀ» °®Ãá ÀÛµ¿ ÆíÀǼºÀ» Á¦°øÇϵµ·Ï ¼³°èµÇ¾ú½À´Ï´Ù.



    Ư ¡


    ¢º 4 °¡Áö ±âº» ±â´É : CC, CV, CR, CP;
    ¢º 8 °¡Áö ±âº» µ¿ÀÛ ¸ðµå : CCL, CCH, CV, CRL, CRM, CRH, CPV, CPC;
    ¢º 24 bit A/D °ú 17 bit D/A ÄÁ¹öÅÍ ÀåÂøÇÏ¿© °íÁ¤¹Ðµµ Á¦°ø
    ¢º Full ºÎÇÏ¿¡¼­ ÃÖ¼Ò µ¿ÀÛ Àü¾Ð 0.6V
    ¢º ¿É¼ÇÀÇ ÀúÀü¾Ð ½ÃÇè ÀåÄ¡·Î µ¿ÀÛ Àü¾ÐÀ» 0V·Î ¼³Á¤ °¡´ÉÇϸç ÀÌ ±â´ÉÀº ¿¬·áÀüÁö, ¼Ö¶ó¼¿°ú »õ·Î¿î ¿¡³ÊÁö½ÃÇè ÀÀ¿ë¿¡ È°¿ë °¡´É
    ¢º º¸È£(protection) ±â´É
    ¢º CPV, CPC ¸ðµå ÀåÂøÀ¸·Î È¿À²ÀûÀÎ CP mode ¿î¿ë;
    ¢º CR mode ÀÇ °³¼±À¸·Î ÀÀ¿ë¹üÀ§ È®´ë
    ¢º °í¼ÓÀÇ ÀüÀÌ(transient) µ¿ÀÛ - High/low level time ¸¦ °¢°¢ ÁöÁ¤ÇÏ°í »ó½Â ÇÏ°­½Ã°£ Á¦¾î
    ¢º ¼øÂ÷ ½ÃÇè(sequential test)±â´É; ÃÖ¼Ò10us ¼³Á¤ ½Ã°£; ÃÖ´ë 10000s ¼³Á¤. ¹Ýº¹ »çÀÌŬ Ƚ¼öÁöÁ¤ °¡´É
    ¢º ´Ü¶ô ½ÃÇè(short-circuit test), ¹èÅ͸® ¹æÀü ½ÃÇè, ±âŸ º¸Á¶ ±â´É
    ¢º È¿À²ÀûÀÎ ³Ã°¢ ½Ã½ºÅÛ ÀåÂø
    ¢º ÀÚµ¿ ON/OFF ±â´É
    ¢º ³ëºê¿Í µðÁöÅÐ Å°¸¦ »ç¿ëÇÑ Æí¸®ÇÑ µ¿ÀÛ
    ¢º Save/recall ±â´É
    ¢º SCPI (Standard Commands for Programmable Instrumentation), Labview, PC software Á¦°ø


    »ç ¾ç


    High Reliability

    ¡Ü Protective circuitry provides over-current, over-voltage, over-power, over-temperature and reverse polarity protection to ensure the protection of the electronic load;

    ¡Ü A high-speed, power limiting circuit can limit input power rapidly when it is overloaded, thus there is no need to interrupt testing. Equipment adaptability to complicated operational environments is thereby greatly enhanced.

    ¡Ü A high-efficiency, intelligent cooling system can effectively reduce system temperature and enhance power density;

    ¡Ü The input binding posts with their innovative design are especially suitable for large current testing. They are easy to operate, reliable and durable;

    ¡Ü The specially ruggedized case with its rubber bumpers protects the load thus effectively prolonging the unit¡¯s service life.



    Great Performance

    ¡Ü Circuit improvement greatly enhances the dynamic response of CR mode and widens the application scope of that mode;

    ¡Ü The innovative CP mode can test voltage sources, current sources, and effectively prevent short-circuits as well when the tested power is insufficient;



    ¡Ü Minimum operating voltage is less than 0.6V at the load's full rated current. With optional low-voltage testing devices, the maximum current can be achieved even though the input voltage is 0V. This is especially suitable for fuel cell, solar cell and other new energy test applications;

    ¡Ü By adopting an optimum design of calculation method and high-speed hardware circuitry, the D/A conversion rate can reach 100kHz. The overall smoothness of slope control has been raised, meanwhile, the timing precision and resolution of dynamic test and sequential test have also been improved;

    ¡Ü The 24 bit A/D and 17 bit D/A converters incorporated, provide this equipment with greatly enhanced setting and measurement resolution.



    Multifunction

    ¡Ü Equipped with four basic test functions: CC, CV,CR, CP;

    ¡Ü High-speed transient operation with separate high/low lever time and rising/falling time control;



    ¡Ü Powerful sequential test function; with a minimum step time of 10us; and a maximum step time of 10000s. Cyclic numbers can be adjusted freely and a sequence can be chained to another sequence to achieve even more complex test procedures;

    ¡Ü Providingshort-circuit test, battery discharge test and other auxiliary functions;

    ¡Ü Remote input terminal and external trigger input terminals are provided. The remote measurement can monitor the input signal automatically, and it is not necessary to change wiring or modify settings during operation;

    ¡Ü 10 groups of setup parameters can be saved, and providing automatic uploading of preset parameters;

    ¡Ü By supporting SCPI, it is easy to build an ATE (automatic test equipment) system that works with other programmable instruments via optional RS232, USB and GPIB interfaces.



    Easy Operation

    ¡Ü Design optimized for portability and rugged reliability;

    ¡Ü Logical keypad design and convenient test operation;

    ¡Ü Easy-to-set test parameters coupled with a powerful sequence editing function;

    ¡Ü All electronic calibration - therefore no need to dismantle the equipment-chassis;

    ¡Ü Firmware can be updated online.



    Specifications

    (The warm-up time is 30 minutes. Specifications indicate warranted performance in the 25¡ÆC ¡¾ 5¡ÆC region of the total temperature range).

    Model
    3720A
    3721A
    3722A
    3723A
    3724A
    Input Ratings
    Current
    Voltage
    Power*1
    0~30A
    0~80V
    250W at 40oC
    0~40A
    0~80V
    400W at 40oC
    0~20A
    0~200V
    200W at 40oC
    0¢¦30A
    0¢¦200V
    350W at 40oC
    0¢¦20A
    0¢¦500V
    0¢¦250W
    Input Characteristics
    Input Characteristics


    Minimum Operation Voltage@Full Scale Current
    0.6V
    0.6V
    1.2V
    1.2V
    2V
    Constant Current Mode
    LowRange
    Resolution
    Accuracy
    0~3A
    0.1mA
    0.1℅+5mA
    0~4A
    0.1mA
    0.1℅+5mA
    0~2A
    0.1mA
    0.1℅+5mA
    0~3A
    0.1mA
    0.1℅+5mA
    0¢¦2A
    0.1mA
    0.1%+5mA
    HighRange
    Resolution
    Accuracy
    0¢¦30A
    1mA
    0.1℅+10mA
    0~40A
    1mA
    0.1℅+10mA
    0~20A
    1mA
    0.1℅+10mA
    0~30A
    1mA
    0.1℅+10mA
    0¢¦20A
    1mA
    0.1%+10mA
    Constant Voltage Mode
    Range
    Resolution
    Accuracy
    0~80V
    1mV
    0.1℅+10mV
    0~80V
    1mV
    0.1℅+10mV
    0~200V
    2mV
    0.1℅+25mV
    0~200V
    2mV
    0.1℅+25mV
    0¢¦500V
    5mV
    0.1%+62.5mV
    Constant Resistance Mode
    LowRange
    Resolution
    Accuracy
    0.02~2¥Ø
    0.1m¥Ø
    0.5℅+12m¥Ø @I>4A
    0.02~2¥Ø
    0.1m¥Ø
    0.5℅+12m¥Ø @I>4A
    0.0666~6.66¥Ø
    0.1m¥Ø
    0.5℅+40m¥Ø@I>3A
    0.0666~6.66¥Ø
    0.1m¥Ø
    0.5℅+40m¥Ø@I>3A
    0.125¢¦12.5¥Ø
    0.1m¥Ø
    0.5%+150m¥Ø @I£¾2A
    MiddleRange
    Resolution
    Accuracy
    2~200¥Ø
    8.6uS*2
    0.3℅+1.25mS@V>8V
    2~200¥Ø
    8.6uS
    0.3℅+1.25mS@V>8V
    6.66~666¥Ø
    2.6uS*2
    0.3℅+375mS@V>20V
    6.6~666¥Ø
    2.6uS*2
    0.3℅+375mS@V>20V
    12.5¢¦1250¥Ø
    13.8uS
    0.3%+1mS @V£¾50V
    HighRange
    Resolution
    Accuracy
    20~2000¥Ø
    0.96uS
    0.3℅+0.625mS@V>8V
    20~2000¥Ø
    0.96uS
    0.3℅+0.625mS@V>8V
    66.6~6660¥Ø
    0.29uS
    0.3℅+188uS@V>20V
    66.6~6660¥Ø
    0.29uS
    0.3℅+188uS@V>20V
    125¢¦12500¥Ø
    1.54uS
    0.3%+0.5mS @V£¾50V
    Constant Power Mode
    Range
    Resolution @P<100W
    @P¡Ã100W
    Accuracy
    0~250W
    1mW
    10mW
    0.2℅+600mW
    0~400W
    1mW
    10mW
    0.2℅+600mW
    0~200W
    1mW
    10mW
    0.2℅+600mW
    ¹«´Ü¼öÁý¹× º¹À縦 ±ÝÇÕ´Ï´Ù .
    »óÇ°Á¤º¸°í½Ã
    Á¦Ç°¸í ÀüÀڷεå, ÇÁ·Î±×·¡¸ÓºíDCÀÏ·ºÆ®·Î´Ð·Îµå, 3722A
    ÆǸŰ¡°Ý 946,000¿ø
    ºê·£µå ARRAY
    Á¦Á¶»ç ARRAY
    °ü·Ã»óÇ°
        
    »ó¼¼¼³¸í »óÇ°Èıâ(0) »óÇ°¹®ÀÇ(0) ±³È¯ ¹× ¹ÝÇ°/¹è¼Û/°áÁ¦
    ¹øÈ£ Á¦¸ñ À̸§ º°Á¡ ³¯Â¥
    ¾ÆÁ÷ ÀÛ¼ºµÈ »óÇ°ÆòÀÌ ¾ø½À´Ï´Ù.
     
    »ó¼¼¼³¸í »óÇ°Èıâ(0) »óÇ°¹®ÀÇ(0) ±³È¯ ¹× ¹ÝÇ°/¹è¼Û/°áÁ¦
    ¹øÈ£ Á¦¸ñ À̸§ ³¯Â¥
    ÀÛ¼ºµÈ »óÇ°¹®ÀÇ°¡ ¾ø½À´Ï´Ù.
      »óÇ°¹®ÀÇÇϱâ
    »ó¼¼¼³¸í »óÇ°Èıâ(0) »óÇ°¹®ÀÇ(0) ±³È¯ ¹× ¹ÝÇ°/¹è¼Û/°áÁ¦
    ¹ÝÇ°±³È¯
    ±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì
    - ±¸ÀÔÈÄ 7ÀÏ À̳»¿¡ µ¿ÀÏÁ¦Ç°À¸·Î ±³È¯ °¡´ÉÇÏ¸ç ¿î¼Ûºñ´Â ÆǸÅÀÚ ºÎ´ãÀÔ´Ï´Ù.
    - ´Ù¸¥ Á¦Ç°À¸·Î ±³È¯, ¶Ç´Â ÀÌ»óÀÌ ¾ø´Â Á¦Ç°°ú ÇÔ²² ±³È¯À» ¿øÇÏ½Ç °æ¿ì ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

    ±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì (»ö»ó,»çÀÌÁî,´Ù¸¥»óÇ°±³È¯)
    - ±¸ÀÔÈÄ 7ÀÏÀ̳» ±³È¯ °¡´ÉÇÏ¸ç ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

    !! ÁÖÀÇ»çÇ×
    ºñ´ÒÆ÷Àå ¹× TagÀÇ Æó±â ¶Ç´Â ÈÑ¼Õ µîÀ¸·Î »óÇ° °¡Ä¡°¡ ¸ê½ÇµÈ °æ¿ì¿¡´Â Á¦ÇÑ.
    ¹ÝÇ°½Ã¿¡ ÇØ´ç »çÀºÇ°ÀÌ ÀÖÀ» °æ¿ì °°ÀÌ º¸³»ÁÖ¼Å¾ß ÇÕ´Ï´Ù.
    ¹è¼Û¾È³»
    °áÁ¦ÈÄ 3~7ÀÏ À̳»¿¡ »óÇ°À» ¹Þ¾Æ º¸½Ç ¼ö ÀÖ½À´Ï´Ù.
    ±¹³» ÃÖ´ëÀÇ ¹°·ù»ç ¿»·Î¿ìĸÅù踦 ÅëÇÏ¿© ½Å¼ÓÇÏ°í ¾ÈÀüÇÏ°Ô ¹è¼ÛµË´Ï´Ù.
    ¸ðµç Á¦Ç°Àº ÂøºÒ ¹ß¼ÛµË´Ï´Ù. ´Ü 30¸¸¿ø ÀÌ»ó ±¸ÀԽà ¹«·á¹è¼ÛÀÔ´Ï´Ù.
    (Á¦ÁÖµµ¸¦ Æ÷ÇÔÇÑ µµ¼­,»ê°£Áö¿ªÀº Ç×°ø·á ¶Ç´Â µµ¼±·á°¡ Ãß°¡µË´Ï´Ù.)
    °áÁ¦¾È³»
    °áÁ¦¹æ¹ýÀº ½Å¿ëÄ«µå, ±¹¹Î/BC(ISP), ¹«ÅëÀåÀÔ±Ý, Àû¸³±ÝÀÌ ÀÖ½À´Ï´Ù.
    Á¤»óÀûÀÌÁö ¸øÇÑ °áÁ¦·Î ÀÎÇÑ ÁÖ¹®À¸·Î ÆÇ´ÜµÉ ¶§´Â ÀÓÀÇ·Î ¹è¼ÛÀÌ º¸·ùµÇ°Å³ª,ÁÖ¹®ÀÌ Ãë¼ÒµÉ ¼ö ÀÖ½À´Ï´Ù.
    • 032-571-0094/0093
      PHONE. 010-2094-2237
      E-MAIL. hysc880@nate.com
    • ¹è¼ÛÁ¶È¸
      ÁÖ¹®ÇϽŠ»óÇ°ÀÇ ¹è¼Û »óÅ°¡
      ¾î¶²Áö ±Ã±ÝÇϽŰ¡¿ä?
    • ½ÅÇÑÀºÇà
      100-028-353897
      ¿¹±ÝÁÖ : (ÁÖ)¿¡ÀÌÄ¡¿ÍÀÌ»ê¾÷
    • ÀÚÁÖÇÏ´Â Áú¹®
      ±Ã±ÝÇϽŠ»çÇ×ÀÌ ÀÖÀ¸½Å°¡¿ä?
      ÀÚÁÖÇÏ´Â Áú¹®¸¸ ¸ð¾Ò½À´Ï´Ù.
    »óÈ£ : (ÁÖ)¿¡ÀÌÄ¡¿ÍÀÌ»ê¾÷     ÁÖ¼Ò : ÀÎõ±¤¿ª½Ã °è¾ç±¸ ÁÖºÎÅä·Î413¹ø±æ32     ´ëÇ¥ÀÚ : ÇãÁ¾¼ø     »ç¾÷ÀÚµî·Ï¹øÈ£ : 121-86-02196 (Á¤º¸È®ÀÎ)
    Åë½ÅÆǸž÷½Å°í : Á¦2015-ÀÎõ°è¾ç-0634È£     ºÎ°¡Åë½Å»ç¾÷ÀÚ¹øÈ£ : 121-86-02196     °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : ±èÈñÁ¤     °³ÀÎÁ¤º¸º¸È£±â°£ : ȸ¿øÅ»Åð½Ã
    È£½ºÆü­ºñ½ºÁ¦°ø¾÷ü :