    ÃÊÀ½ÆÄŽ»ó±â ,TruSonic II , Tru-sonic Plus ÃÊÀ½ÆÄŽ»ó±â TRUSONIC II ULTRASONIC FLAW DETECTOR
    ÆǸŰ¡°Ý 7,200,000¿ø
    ¿ø»êÁö keiyu
    ºê·£µå keiyu
    Á¦Ç°ÄÚµå TRU-SONICII-700
    ÁÖ¹®¼ö·®
    »ó¼¼¼³¸í »óÇ°Èıâ(0) »óÇ°¹®ÀÇ(0) ±³È¯ ¹× ¹ÝÇ°/¹è¼Û/°áÁ¦




    DIGITAL ULTRASONIC FLAW DETECTOR

    TruSonicII hand held and light weight Digital Ultrasonic Flaw Detector offers you all the features of larger, heavier instruments,
    such as high resolution with the usual high gain reserve.
    In addition to this, the instruments ease work by the inclusion of extras. For example in weld testing the exact flaw location is evaluated;
    all features are available for demanding thickness measurements.
    User-friendly programs for display evaluation with 3 or 4 Distance Amplitude Curves (DAC), +6dB DAC and for AVG evaluation are available as standard.
    T-Scan thickness display and optional Encoder B-scan Scanner
    Welding simulation map for welding section display defect location for report printing
    The light weight 2.5 kg, including batteries!
    The ergonomic design and operational ease will amaze you.
    Large Color TFT display. A bright, 400 cd/m2 high contrast screen enables you to read your measurements data even under poor lighting conditions.
    The A-Scan, the instrument settings and the digital measurement readings are all displayed simultaneously.
    The instruments can withstand the toughest condition. After testing, you will certainly wish to use the many documentation possibilities to record all
    calibration parameters and test results. It could storage 500 data inside.
    INSTRUMENTS MEET YOUR NEEDS
    The high refresh rate (60Hz) of the bright and high-contrast TFT screen is reminiscent of the successful analog tubes.
    You can read your measurement readings quickly and clearly. If a measurement is made when you are at some distance from your instrument,
    simply display the reading in large digits.
    The pulse repetition frequency can be reduced. By doing this, phantom echoes can be reliable avoided which could occur when testing larger tes
    t objects.
    The instrument can store data sets, including all instrument parameters, test results and A-Scans and can be recalled at any time.
    You soon feel at ease, because you operate them in accordance with your proven standards for digital instruments.
    FEATURES

    joystick control set and adjust all parameters
    Welding simulation map
    Large thickness reading display
    DAC curve with DAC alarm
    Curve DGS ( optional)
    Positive, negative, and minimum depth alarms
    Filled waveform trace display
    Separately Gate A and Gate B setting with alarm

    Peak or Flank measurement
    Freeze and Peak memory mode
    Automatic calibration on two points
    Pulse repetition frequency control
    Displays sound path value, surface distance and depth to flaw
    in angle beam inspections
    Connects to PC via USB cable to download data and make
    certificates





















     

    TECHNICAL SPECIFICATIONS
    Calibration range:
    From 25 to 6000 mm (steel long)
    Sound velocity:
    2 fixed values(3230m/s,5920m/s) and adjustable in the range 1000 to 9999m/s in steps of 1m/s
    Probe delay:
    0 to 365 ¥ìs
    Gain:
    100dB, adjustable in steps of 0.1/2/6/12/20 dB
    Fine Gain:
    0.1 dB
    Frequency range:
    0.5-10 MHz wide band
    Pulse repetition frequency:
    10-1000Hz, depending on the set calibration range and the probe delay for adjustable
    Test methods:
    Pulse echo mode and Thru mode
    Pulse Voltage:
    300 V negative spike
    Damping:
    120 ohm
    Echo presentation:
    Full wave
    Suppression:
    Linear, 0 to 90% screen height adjustable in steps of 1%, status indication on the display
    DAC:
    Recording of up to 8 reference echoes, 40dB dynamic range,
    display of the DAC curve 3 or 4 DAC curve can be setting
    DGS:
    Measurement technique that allows defects echoes through the evaluation of diagrams DGS associated with particolar probes and materials.
    Data storage:
    500 A-scan Trace Data sets in the FLASH memory, with additional alphanumeric identification and directory function
    Units of measure:
    mm or inch
    Interface:
    USB
    Probe connector:
    Two LEMO 1 connectors or BNC Connector
    Power supply:
    Removable 13.2Ah/ 3.7 V Li-ion Battery or mains supply via an
    external mains power/charger unit JBD15-A2S
    Operational period:
    Up to 6 hours with Battery ( select LCD low bright )
    Operating temperature:
    -5¡Æ C +65¡Æ C
    Storage temperature:
    -40¡Æ C +75¡Æ C (without batteries)
    Display size:
    110mm ¡¿ 62mm (W¡¿H)
    Dimensions:
    145mm ¡¿ 210mm ¡¿4 5mm (H¡¿W¡¿T)

    ¹«´Ü¼öÁý¹× º¹À縦 ±ÝÇÕ´Ï´Ù .
    »óÇ°Á¤º¸°í½Ã
    Á¦Ç°¸í ÃÊÀ½ÆÄŽ»ó±â ,TruSonic II , Tru-sonic Plus ÃÊÀ½ÆÄŽ»ó±â TRUSONIC II ULTRASONIC FLAW DETECTOR
    ÆǸŰ¡°Ý 7,200,000¿ø
    ºê·£µå keiyu
    ¿ø»êÁö keiyu
    °ü·Ã»óÇ°
        
    »ó¼¼¼³¸í »óÇ°Èıâ(0) »óÇ°¹®ÀÇ(0) ±³È¯ ¹× ¹ÝÇ°/¹è¼Û/°áÁ¦
    ¹øÈ£ Á¦¸ñ À̸§ º°Á¡ ³¯Â¥
    ¾ÆÁ÷ ÀÛ¼ºµÈ »óÇ°ÆòÀÌ ¾ø½À´Ï´Ù.
     
    »ó¼¼¼³¸í »óÇ°Èıâ(0) »óÇ°¹®ÀÇ(0) ±³È¯ ¹× ¹ÝÇ°/¹è¼Û/°áÁ¦
    ¹øÈ£ Á¦¸ñ À̸§ ³¯Â¥
    ÀÛ¼ºµÈ »óÇ°¹®ÀÇ°¡ ¾ø½À´Ï´Ù.
      »óÇ°¹®ÀÇÇϱâ
    »ó¼¼¼³¸í »óÇ°Èıâ(0) »óÇ°¹®ÀÇ(0) ±³È¯ ¹× ¹ÝÇ°/¹è¼Û/°áÁ¦
    ¹ÝÇ°±³È¯
    ±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì
    - ±¸ÀÔÈÄ 7ÀÏ À̳»¿¡ µ¿ÀÏÁ¦Ç°À¸·Î ±³È¯ °¡´ÉÇÏ¸ç ¿î¼Ûºñ´Â ÆǸÅÀÚ ºÎ´ãÀÔ´Ï´Ù.
    - ´Ù¸¥ Á¦Ç°À¸·Î ±³È¯, ¶Ç´Â ÀÌ»óÀÌ ¾ø´Â Á¦Ç°°ú ÇÔ²² ±³È¯À» ¿øÇÏ½Ç °æ¿ì ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

    ±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì (»ö»ó,»çÀÌÁî,´Ù¸¥»óÇ°±³È¯)
    - ±¸ÀÔÈÄ 7ÀÏÀ̳» ±³È¯ °¡´ÉÇÏ¸ç ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

    !! ÁÖÀÇ»çÇ×
    ºñ´ÒÆ÷Àå ¹× TagÀÇ Æó±â ¶Ç´Â ÈÑ¼Õ µîÀ¸·Î »óÇ° °¡Ä¡°¡ ¸ê½ÇµÈ °æ¿ì¿¡´Â Á¦ÇÑ.
    ¹ÝÇ°½Ã¿¡ ÇØ´ç »çÀºÇ°ÀÌ ÀÖÀ» °æ¿ì °°ÀÌ º¸³»ÁÖ¼Å¾ß ÇÕ´Ï´Ù.
    ¹è¼Û¾È³»
    °áÁ¦ÈÄ 3~7ÀÏ À̳»¿¡ »óÇ°À» ¹Þ¾Æ º¸½Ç ¼ö ÀÖ½À´Ï´Ù.
    ±¹³» ÃÖ´ëÀÇ ¹°·ù»ç ¿»·Î¿ìĸÅù踦 ÅëÇÏ¿© ½Å¼ÓÇÏ°í ¾ÈÀüÇÏ°Ô ¹è¼ÛµË´Ï´Ù.
    ¸ðµç Á¦Ç°Àº ÂøºÒ ¹ß¼ÛµË´Ï´Ù. ´Ü 30¸¸¿ø ÀÌ»ó ±¸ÀԽà ¹«·á¹è¼ÛÀÔ´Ï´Ù.
    (Á¦ÁÖµµ¸¦ Æ÷ÇÔÇÑ µµ¼­,»ê°£Áö¿ªÀº Ç×°ø·á ¶Ç´Â µµ¼±·á°¡ Ãß°¡µË´Ï´Ù.)
    °áÁ¦¾È³»
    °áÁ¦¹æ¹ýÀº ½Å¿ëÄ«µå, ±¹¹Î/BC(ISP), ¹«ÅëÀåÀÔ±Ý, Àû¸³±ÝÀÌ ÀÖ½À´Ï´Ù.
    Á¤»óÀûÀÌÁö ¸øÇÑ °áÁ¦·Î ÀÎÇÑ ÁÖ¹®À¸·Î ÆÇ´ÜµÉ ¶§´Â ÀÓÀÇ·Î ¹è¼ÛÀÌ º¸·ùµÇ°Å³ª,ÁÖ¹®ÀÌ Ãë¼ÒµÉ ¼ö ÀÖ½À´Ï´Ù.
    • 032-571-0094/0093
      PHONE. 010-2094-2237
      E-MAIL. hysc880@nate.com
    • ¹è¼ÛÁ¶È¸
      ÁÖ¹®ÇϽŠ»óÇ°ÀÇ ¹è¼Û »óÅ°¡
      ¾î¶²Áö ±Ã±ÝÇϽŰ¡¿ä?
    • ½ÅÇÑÀºÇà
      100-028-353897
      ¿¹±ÝÁÖ : (ÁÖ)¿¡ÀÌÄ¡¿ÍÀÌ»ê¾÷
    • ÀÚÁÖÇÏ´Â Áú¹®
      ±Ã±ÝÇϽŠ»çÇ×ÀÌ ÀÖÀ¸½Å°¡¿ä?
      ÀÚÁÖÇÏ´Â Áú¹®¸¸ ¸ð¾Ò½À´Ï´Ù.
    »óÈ£ : (ÁÖ)¿¡ÀÌÄ¡¿ÍÀÌ»ê¾÷     ÁÖ¼Ò : ÀÎõ±¤¿ª½Ã °è¾ç±¸ ÁÖºÎÅä·Î413¹ø±æ32     ´ëÇ¥ÀÚ : ÇãÁ¾¼ø     »ç¾÷ÀÚµî·Ï¹øÈ£ : 121-86-02196 (Á¤º¸È®ÀÎ)
    Åë½ÅÆǸž÷½Å°í : Á¦2015-ÀÎõ°è¾ç-0634È£     ºÎ°¡Åë½Å»ç¾÷ÀÚ¹øÈ£ : 121-86-02196     °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : ±èÈñÁ¤     °³ÀÎÁ¤º¸º¸È£±â°£ : ȸ¿øÅ»Åð½Ã
    È£½ºÆü­ºñ½ºÁ¦°ø¾÷ü :